Standing Floor Air Purifier SAP 1000

img_801f_1b

img_801f_2bAll metal built with rock solid quality

The all metal housing SAP1000 unit is a reliable electronic air purifier.

The air purifier features multi-stage air purification process technologies, including the washable and reusable 2-stage electronic cell, activated carbon filter and UV-photo catalytic system to eliminate particles, toxic gases and various microorganisms that pass through the system.The power supply of the unit is self-regulating to maintain peak efficiency to accommodate a wide range of cell dirt loading conditions.

The product is ideal for commercial, medical or industrial environment because it offers complete protection and does not generate any chemical odors by utilizing none chemical substances nor plastic materials.


img_801f_3Big size powerful two-stage electronic cell

The unit equips with a big size electronic cell to capture fine particles down to 0.3 microns. The cell is reusable after cleaning and offers benefits over other disposable air filters which require expensive replacement filters and it can even become "production bed" for many harmful forms of bacteria.

 


 

img_801f_4Smart check alarm system

The unit equips with a programmable power supply so that the CHECK light will beep and flash when it finds a problem in the cell-power supply system.

 

 


img_801f_5Powerful UV light-photo catalytic system

The unit uses 2x24W UV bulbs to kill the microorganisms immediately and decomposes many kinds of organic compounds by photo catalytic filter.

 

 


Product description

  • The washable metal mesh pre-filter captures large particles to contribute the other filters longer filter lifetime.
  • The electronic cell discloses a negative charge to particles that pass through the unit and collects them on opposite charged metal plates. The electronic cell can capture particles down to a size of 0.01 micron. It is easy to clean and needs low maintenance.
  • The activated carbon filter locks in chemicals and odors. It will continue working for many months before replacement.
  • UV-C light can destroy airborne microorganisms such as bacteria, mold, and viruses.
  • Photo catalyst can effectively reduce odors and restrain the activity of microorganisms. The use of photo catalyst is permanent and does not need replacement.
  • The negative ion generator releases the high concentration level of negative ions to make the air more pure and fresh.

img_801f_6UV light

"Ultraviolet" means "beyond violet" (from Latin ultra, "beyond") and violet is the color of visible light with highest frequency. UV light is an invisible form of electromagnetic radiation that has a shorter wavelength than that of light human can see. It carries more energy than visible light and can even break bonds between atoms and molecules that altering its chemistry configuration of materials exposed to it. In the visible part of the spectrum, wavelength decreases — and the energy of the electromagnetic waves increases — from red through orange, yellow, green, blue and violet, so UV light has a shorter wavelength with more energy than violet light do. Wavelength is measured in nanometers (nm), and ultraviolet wavelengths range between 10nm and 400nm. It can be classified as UV-A, UV-B or UV-C in order of decreasing wavelength.

Ultraviolet light kills microorganisms by damaging their DNA. UV radiation causes the nucleic acids in DNA to break their bonds and pair incorrectly. This causes the DNA to be either unreadable or misread so that it causes bacteria or viruses unable to carry out their normal functions or reproduce correctly. If the damage is severe enough the bacteria cannot repair the damage so it dies.

img_801f_7

Control Panel

INDICATOR LIGHTS:

  • CHECK/FILTER REPLACEMENT indicator light: When the machine breaks down, the indicator light flashes red with beeping. When the indicator light flashes yellow, the activated carbon filter needs to be replaced.
  • AIR POLLUTANT indicator light
  • TIMER indicator light
  • SPEED indicator light
  • Auto mode indicator light: When this indicator is lighting up, the unit is at Auto mode.
  • NIGHT indicator light: When the NIGHT button on the remote control is pressed the light will light up.
  • NEG.ION indicator light
  • UV LAMPS indicator light: The indicator light will light up when the UV light are on. When the indicator light flashes, it tells the time for UV lamp replacement.

BUTTONS:

  • A- POWER Button
  • Turns the purifier On and Off.
  • B- SPEED Button
  • When the SPEED button is pressed the airflow rate changes as show below: L -- M -- H -- a (auto mode).
  • C- TIMER Button
  • Press the TIMER button to select the time for operation. The timer setting switches as shown: c (timer cycle function) -- 1hr -- 2hr -- 4hr -- cancel timing.
  • D- NEG.ION Button
  • When pressed, the generation of ions will cease and the negative ion generator light will go out.
  • E- UV LAMP Button
  • When the button is pressed, it will turn off the UV lamp, pressing again will turn on the UV light.

Easy and low cost maintenance

When the filters needs to be washed or replaced, just open the front panel, lift out the old filters and drop the new ones in. No tools are required.Unplug the unit.

  • Open the filter cabinet and pull straight the pre filter. Clean the metal mesh pre filter by using a vacuum cleaner or rinse it. Dry the pre filter thoroughly before placing back into the unit.
  • Take out the electronic cell from the filter cabinet. Cleaning the cell in the dishwasher or submerge it in the sink or bathtub. Dry the cell completely before putting back into the cabinet.
  • Replace the carbon filter when the replace filter indicator light flashes.
  • Replace the UV lamp when the UV lamp indicator light flashes.

img_801f_9

img_801f_10

Specifications

img_801f_11-2

Model SAP 1000
Power requirement a.c220V, 50Hz
Rated Power Max. 230.6W
Motor 220V, 50Hz
Noise Level <50dB (A)
Negative Ion 3x10/cm3
UV Lamp 2x24W
Fuse a.c250V, 2A
Main parts Pre filter, electronic cell, activated carbon filter,
UV lamp and photo catalyst, negative ion generator
Dimensions W525mm x D477mm x H1545mm
Weight 63kg
Speed 3 Speeds
Timer 1 hr, 2 hr, 4 hr
Alarm light The indicator lights for cell cleaning, activated carbon filter replacement and UV lamp replacement.
Power cord 3 phase power cord, L=3m
Operation Button operation, remote control operation

 